Technical Service

Application of Variable Frequency Speed Control System in Decanter Centrifuge


summary : Application of Variable Frequency Speed Control System in Decanter Centrifuge
  Application of Variable Frequency Speed Regulation System in Decanter Centrifuge
 
  I. Load Characteristics of the Decanter Centrifuge's Back Drive Device
 
  The speed regulating device installed at the small shaft end of the decanter centrifuge's differential is called the back drive device. These devices include: eddy current brakes; asynchronous motors; hydraulic motors; mechanical overload protection devices (such as when the small shaft speed is zero). When the screw lags behind the drum, these devices use the centrifuge's kinetic energy to apply a braking torque to the small shaft, thereby achieving the purpose of adjusting the differential speed. For the small shaft, the back drive device is a negative load.
 
  In the decanter centrifuge's general variable frequency speed regulation system, the motor connected to the differential's small shaft is in a regenerative state for a long time, operating in the fourth quadrant, receiving mechanical energy from the centrifuge and feeding the regenerative braking energy back to the variable frequency drive's DC bus, which is then dissipated through a braking resistor.
 
  How to recover this part of the energy is a topic of great concern to centrifuge manufacturers at home and abroad.
 
  Using a special four-quadrant variable frequency drive, the regenerative energy can be directly fed back to the power grid, but the variable frequency drive is expensive and is rarely used domestically except in rolling mills. The DS706 large wastewater treatment centrifuge produced by the company in recent years uses a dual variable frequency energy feedback energy-saving frequency control system.
 
  II. Structure and Characteristics of the Common DC Bus AC Variable Frequency Speed Regulation System
 
  1-Main Inverter; 2-Main Motor; 3-Centrifuge; 4-Differential; 5-Auxiliary Motor; 6-Auxiliary Inverter;
 
  Structure of the Common DC Bus AC Variable Frequency Speed Regulation System
 
  The centrifuge 3 is driven by the main motor 2, and the differential's small shaft and the auxiliary motor 5 are connected coaxially. The speeds of the main and auxiliary motors are controlled by the inverters 1 and 6, and their DC buses are connected in parallel, with the three-phase power supply inputting to the main inverter 1.
 
  Characteristics:
 
  (1) Excellent energy-saving performance: When the screw lags, the regenerated energy is sent to the DC bus of the auxiliary inverter. Because the DC buses of the main and auxiliary inverters are connected in parallel, this energy is used by the main motor through the main inverter.
 
  For simplicity, assuming that the centrifuge operates at a constant torque and constant differential speed in a steady state (neglecting the effects of acceleration torque and deceleration torque during speed regulation), the recovered energy is: P = 0.8M n/9550, where: P - power (KW); M - small shaft torque (N.m); n - small shaft speed (r/min); The 0.8 times before M is due to the fact that even without adding a discharge braking resistor during regenerative braking, 20% of the motor's internal energy is converted into braking torque.
 
  (2) Fast dynamic response: Some PID control systems often have overshoot phenomena, and the transition process time is relatively long, such as the eddy current brake speed regulation system, the stabilization period sometimes lasts for several minutes. The variable frequency speed regulation system's torque response time is only 150~200ms, and the dynamic characteristics are significantly improved.
 
  (3) Easy to handle the accumulation of materials in the drum caused by sudden events: When the auxiliary motor reverses, it operates in the first quadrant (motor state), and at this time the differential speed is large: Δn = (nl+n)/i, (nl - drum speed r/min; i - differential speed ratio). Because the variable frequency drive has a static starting torque of 2 times the rated torque, it makes it easy to discharge the material accumulated in the drum.